Main dimensions:
PYROSTAR DUO - only boiler |
18, 25 | 30, 50 |
A | 1000 | 1200 |
B | 530 | 530 |
C | 820 | 1020 |
D | 265 | 265 |
E | 830 | 1000 |
F | 1270 | 1440 |
G | 1110 | 1270 |
H | 65 | 65 |
I | 230 | 230 |
Boiler schema :
Key:
- front cover door
- removable cover of the frame
- handling of the heating flap
- heating flap
- feed door
- grate door
- lower door
- ashtray
- side parts from firebeton LACFIRE
- servomotor of secondary air Belimo
- servomotor of primary air Belimo
- grate inserts from firebeton LACFIRE
- socket of the combustion chamber from firebeton LACFIRE
- brick for secundary air from firebeton LACFIRE
- primary jet from firebeton LACFIRE
- thermal insulation
- combustion chamber from firebeton LACFIRE
- chimney
- flue gases temperature probe
- lambda probe Bosch LSU 4.9
- exhaust fan EBM-PAPST
- propeller of the exhaust fan EBM-PAST
- cells of heating exchanger
- flue rectifier
-
microprocessor regulator AK5000
Main technical datas:
MODRATHERM PYROSTAR Duo | |||||
Typ | PYROSTAR Duo 18 | PYROSTAR Duo 25 | PYROSTAR Duo 30 | PYROSTAR Duo 50 | |
Datas for pellet burning | |||||
Output range | kW | 6 - 18 | 6,7 - 25 | 7,1 - 30 | 12 - 40 |
Boiler operation and ignition | - | automatic | |||
Emmisions boiler class (EN 303-5) | - | 5 | 5 | 5 | 5 |
Recommended fuel (EN 303-5) | - | Pellets C1 according to Ö Norm, d = 6 - 10 mm | |||
Efficiency | % | 86,5 - 90,4 | |||
Chimney draft |
mbar | 6 - 18 | |||
Average flue gases temperature | °C | 75 - 140 | 73 - 165 | 78 - 170 | 87 - 187 |
Flowquantity of fuel | kg/hour | 1,39 - 4,26 | 1,56 - 5,6 | 1,56 - 6,68 | 2,72 - 8,83 |
Fuel consumption | kg/hour | 1,48 - 4,25 | 1,6 - 5,6 | 1,7 - 6,8 | 2,7 - 8,7 |
Elektricty consumption by pellet burning (boiler, burner, feeding) | |||||
by nominal output | W | 56 | 56 | 110 | 110 |
by minimal output | W | 25 | 25 | 50 | 50 |
by STAND BY | W | 5 | 5 | 5 | 5 |
Emmisions by nominal output | |||||
CO by 10% O2 | mg/m3 | 344 | 198 | 208 | 418 |
OGC by 10% O2 | mg/m3 | 7 | 20 | 19 | 3 |
Dust by 10% O2 | mg/m3 | 11 | 12 | 13 | 15 |
CO by 13% O2 | mg/m3 | 250 | 144 | 151 | 298 |
Dust by 13% O2 | mg/m3 | 8 | 9 | 10 | 11 |
CO | mg/MJ | 162 | 93 | 98 | 194 |
OGC | mg/MJ | 3 | 9 | 9 | 1 |
Dust | mg/MJ | 5 | 6 | 6 | 7 |
Emmisions by minimal output | |||||
CO by 10% O2 | mg/m3 | 192 | 113 | 119 | 153 |
OGC by 10% O2 | mg/m3 | 11 | 9 | 9 | 6 |
Dust by 10% O2 | mg/m3 | 38 | 21 | 22 | 37 |
CO by 13% O2 | mg/m3 | 140 | 82 | 86 | 111 |
Dust by 13% O2 | mg/m3 | 27 | 15 | 16 | 27 |
CO | mg/MJ | 91 | 52 | 55 | 72 |
OGC | mg/MJ | 5 | 4 | 4 | 3 |
Dust | mg/MJ | 18 | 10 | 11 | 17 |
Datas for wood burning | |||||
Nominal output | kW | 22 | 26 | 32/39 | 45 |
Boiler operation | - | manually | |||
Recommended fuel (EN 303-5) | - | soft and hard wood, wood briquets, max. moisture 20% | |||
Efficiency | % | 89 - 91 | |||
Chimney draft | mbar | 20 - 25 | |||
Average flue gases temperature | °C | 136 - 160 | |||
Combustion space | dm3 | 108 | 108 | 187 | 187 |
Elektricity consumption by wood burning (boiler) | |||||
by nominal output | W | 69 | 69 | 71 | 71 |
by STAND BY | W | 3 | 3 | 3 | 3 |
Generally | |||||
Water volume | l | 80 | 80 | 118 | 118 |
Temperature range of thermostat | °C | 65 - 85°C | |||
Min. temperature of return water | °C | 65 | |||
Max. working pressure | bar | 2,5 | |||
Max. working pressure of security heat exchanger | bar | 6 | |||
Boilers dimensions (w x h x d) | mm | 530 x 1260 x 1000 | 530 x 1430 x 1200 | ||
Dimensions of ash tray (w x h x d) | mm | 380 x 70 x 520 | 380 x 70 x 720 | ||
Dimensions of loading hole (w x h) | mm | 390 x 490 | 390 x 510 | ||
Overall weight | kg | 425 | 425 | 566 | 581 |
Overall weight with burner set | kg | 511 | 511 | 656 | 671 |
Chimney connection | mm | 152 | |||
Power supply / frequency | V/Hz | 230/50 | |||
Elektricity cover | IP | 40 |